What If your entire data center could be deployed in weeks instead of months? NPod micro data center is a compact and ready-to-deploy infrastructure that combines computing, storage, cooling, and power into one single integrated system. Designed for businesses that need faster, flexible, and efficient IT environment without complex setups.
A micro data center is a compact, self-contained IT infrastructure unit that brings together all essential components such as servers, storage, networking, power, cooling, and monitoring inside a secure enclosure. It delivers the performance, reliability, and uptime of a traditional data center in a much smaller and easy to deploy setup, making it ideal for edge locations, office, and remote environments. Its core Components Includes:
NPod micro edge data center allows businesses to process data closer to the source, reducing latency and improving speed. This makes it ideal for AI, IoT, and real-time applications. Instead of relying on distant infrastructure, it ensures faster performance, better control, and improved user experiences.
Ideal use case:
Key benefits:
NPod micro data center rack integrates cooling system, power system, fire system, and a smart monitoring system.
NPod micro data center is a fully integrated solution built for security, efficiency, and smart control. It combines power, cooling, monitoring, and protection into one compact system while delivering reliable performance, real time visibility, and easy scalability for modern IT environments.
Secure Protection
Energy Efficiency
Smart Monitoring
High Flexibility
Rack System
Security System
Fire System
Selecting the right micro data center companies ensures better performance, reliability, and long-term scalability. NPod stands out with secure, modular, and easy-to-deploy infrastructure designed for modern business needs. Key features include:
NPod is an advanced indoor micro data center designed to simplify and secure edge IT infrastructure. Built for remote and distributed environments, it delivers centralized control, high flexibility, and energy-efficient performance within a single, integrated system.
Before comparing both, it is important to understand how business needs have evolved. Today, companies need faster deployment, better performance, and flexible infrastructure for modern workloads. This is where solutions like NPod micro data center offers a smarter and more efficient alternative to traditional setups.
The comparison below clearly shows the different in speed, simplicity, and overall value.
| Feature | Traditional Data Center | NPod Micro Data Center |
|---|---|---|
| Deployment Time | Months | Weeks |
| Space Requirement | High | Compact |
| Cooling Setup | Separate Systems | Built-in |
| Monitoring | Complex | Unified Dashboard |
| Scalability | Slower | Modular |
| Cost Efficiency | Higher Initial Cost | Optimized Investment |
Ideal for offices, server rooms, and branch locations. Easy to install and maintain in climate-controlled environments.
Built tough for harsh environments — weatherproof and rugged with IP55 enclosures for outdoor and remote deployments.
Today’s businesses need infrastructure that can grow as fast as their demand. NPod delivers rapid deployment, high efficiency, and consistent performance, without the delays of traditional setups.
Whether it’s an office, industrial site, or remote location, these solutions fit seamlessly into different environments. With built-in cooling, power, and monitoring, they simplify infrastructure management while keeping operations efficient, reliable, and easy to control.
NPod micro data center for AI is built to handle high-performance workloads such as machine learning and GPU computing. These environments require strong power support, efficient cooling, and low latency. NPod helps businesses run AI applications faster and more efficiently while maintaining control and reliability.
Powered by advanced hardware options such as NVIDIA H200 GPUs, NPod enables faster AI processing while maintaining efficiency, uptime, and control.
The micro data setup cost India depends on how your infrastructure is designed, especially when using advanced solutions like NPod. Instead of heavy construction and long deployment cycle, NPod offers a pre integrated and modular approach that helps reduce overall time and initial investment.
Cost Factors That Influence Pricing:
As business move toward AI, automation, edge compuiting, and real time digital operations,traditional infrastructure often become slow and expensive to scale. NPod is designed to meet these modern demands with smarter and more efficient approach.
NPod provides a smarter alternative with:
Designed for performance. Built for scalability.

3k–6k MDC with integrated UPS & closed cooling.

5k–10k MDC with row-based airflow design.

3k–10k rack-based cooling for edge deployments.

6k–20k split cooling for scalable rack rows.
Full product specifications across all NPOD model variants. Scroll horizontally to view all columns. Customize configuration available on request.
| Product Model | NPOD-03-H01W | NPOD-06-H02W | NPOD-6-H01K | NPOD-10-H02K | NPOD-10-H02R | NPOD-20-H03K | Customize |
|---|---|---|---|---|---|---|---|
| Available Space for IT — U | 33U | 71U | 26U | 66U | 69U | 94U | ≤ 142U |
| Available Power for IT — kW | 1.3 | 2.5 | 3.5 | 5.0 | 7.0 | 12.0 | Per Definition |
| Redundancy | N | N | N | N+1 / 2N | N+1 / 2N | N+1 / 2N | Per Definition |
| Width — mm | 900 | 1810 | 900 | 1810 | 1810 | 2600 | >2600 |
| Depth — mm | 1080 | 1080 | 1080 | 1080 | 1080 | 1080 | Per Definition |
| Height — mm | 2105 | 2105 | 2105 | 2300 | 2300 | 2300 | Per Definition |
| Weight — kg | 165 | 345 | 260 | 1160 | 1160 | 1242 | Per Definition |
| IP Level | IP54 | IP65 | IP65 | IP65 | IP65 | IP65 | Per Definition |
| Input Power | 208-240V/2P/60Hz | 208-240V/2P/60Hz | 208-240V/2P/60Hz | 208-240V/2P/60Hz | 208-230V/3P/50-60Hz | 208-230V/3P/50-60Hz | Per Definition |
| Recommended Breaker | 32A 1P | 63A 1P | 63A 1P | 63A 3P | 63A 3P | 63A 3P | Per Definition |
| Power Section | |||||||
| UPS x kVA | Optional | Optional | Optional | 10.0 | 13.0 | 20.0 | 3 – 200kVA |
| UPS Mount Type | Optional | Optional | Rack | Rack | Rack | Rack | Per Definition |
| Standard UPS Battery | Optional | Optional | 2× VRLA 12V9AH 16PCS | 2× VRLA 12V9AH 16PCS | 2× VRLA 12V9AH 16PCS | 4× VRLA 12V9AH 16PCS | < 4 hour |
| AC PDU | 1× Basic 8 Slots | 2× Basic 8 Slots | 1× Basic 16 Slots | 2× Basic 16 Slots | 2× Basic 16 Slots | 3× Basic 16 Slots | 4× Configurable |
| -48VDC — A | 2× 30A | 30A | Optional | Optional | Optional | Optional | 0 – 600A |
| Standard 48VDC Battery | Lithium 1× 48V50AH | Lithium 1× 48V50AH | Optional | Optional | Optional | Optional | < 4 hour |
| 48VDC Power Distribution | BLVD 63A/Terminals | BLVD 63A/Terminals | 3× 63A/Terminals | Optional | Optional | Optional | Per Definition |
| Cooling Section | |||||||
| Cooling Type | Packaged DX | Packaged DX | Split DX | Split DX | Split DX | Packaged / Split | Custom |
| Mount Type | Wall | Wall | Rack | Rack | Row | Wall / Rack / Row | Custom |
| Capacity — kW | 1.5 | 2×1.5 | 3.9 | 5.9 | 7.6 | 12.8 | 1.5 – 90.0kW |
| DCIM Section | |||||||
| Local Display | Touch Screen | Touch Screen | Touch Screen | Touch Screen | Touch Screen | Touch Screen | Touch Screen |
| Remote Access | Web Access | Web Access | Web Access | Web Access | Web Access | Web Access | Web Access |
| Reporting Protocol | Modbus-TCP | Modbus-TCP | Modbus-TCP | Modbus-TCP | Modbus-TCP | Modbus-TCP | Modbus-TCP |
| UPS Mgmt. | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Cooling Mgmt. | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Temp. & Hum. Sensor | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Fire Sensor | Smoke | Smoke | Smoke | Smoke | Smoke | Smoke | Smoke |
| Water Sensor | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Door Sensor | Front/Rear | Front/Rear | Front/Rear | Front/Rear | Front/Rear | Front/Rear | Front/Rear |
| Security Section | |||||||
| Access Control | RFID/Key | RFID/Key | RFID/Key | RFID/Key | RFID/Key | RFID/Key | RFID/Key |
| Video Surveillance | Optional | Optional | Optional | Optional | Optional | Optional | Optional |
| Fire Fighting Section | |||||||
| Fire Extinguisher | FM200 Rack Module (Opt.) | FM200 Rack Module (Opt.) | FM200 Rack Module (Opt.) | FM200 Rack Module (Opt.) | FM200 Rack Module (Opt.) | FM200 Rack Module (Opt.) | FM200 Rack Module (Opt.) |
| Early Detection | Vesda (Opt.) | Vesda (Opt.) | Vesda (Opt.) | Vesda (Opt.) | Vesda (Opt.) | Vesda (Opt.) | Vesda (Opt.) |